The MO-5898-100A high current micro-ohmmeter, uses the methodology of Kelvin (4 terminals) to avoid measurement errors caused by jump leads and their contact resistances.
The accuracy of the equipment is guaranteed by a last generation signal amplification system, offset and high stability free. The reading is in direct liquid crystal display indicating up to 4 ½ digits.
The equipment is extremely easy to use and carry, weighing approx. 11 kg. His case is sturdy with protection degree IP54 (with lid closed). Cables and accessories are packed in a suitcase that allows storage and transport safe and comfortable.
It has data outputs to connect to a printer and to download measurements stored in the internal memory of 50 records for up to 80 readings each, allowing documentation of measured values.
The system of high current generation is based on a modern technology to reduce weight and size. The plastic enclosure provides high impact resistance and environmental challenges. Internal thermal sensors in all sensitive components in the instrument prevent any damage due to overheating.
The extended range of ambient operating temperature from -5 °C to 50 °C, allows use this equipment in extreme weather conditions, from the cooler regions to tropical regions, presenting a great performance both in fieldwork and in the laboratory.
Specifications
TEST CURRENTS
Up to 100 A (True DC).
The test current can be set between 10% and 100% of the working stream with a resolution of 1 A.
RESISTANCE RANGES
0.1 µΩ to 300 mΩ.
MEASUREMENT PRINCIPLE
Four-terminal, Kelvin-type.
THERMAL PROTECTION
Protects all sensitive components, avoiding any damage due to overheating.
PROGRAMMABLE TEST TIME
Allows to setup the test time from 5 seconds up to 120 seconds.
BASIC ACCURACY
± 1 % of reading ± 1 digit.
ADVANCED FEATURES
Digital direct reading of very low resistances in the alphanumerical display, with up to 4½ digits.
Very fast and accurate measurements.
BUILT-IN PRINTER
Allows print the measured values.
BUILT-IN MEMORY
Capacity to store 50 registers with 80 readings each.
SERIAL DATA OUTPUT
USB.
TINSLEY SOFTWARE
Friendly, easy to use software. With automatic report generator, including the operator's commentaries.
ENVIRONMENTAL
IP54 with closed lid.
SAFETY CLASS
Meets the requirements of IEC 61010-1.
POWER SUPPLY
Mains: 90-240 V~ 50/60 Hz auto.
OPERATING TEMPERATURE RANGE
-5 °C to +50 °C.
STORAGE TEMPERATURE RANGE
-25 °C to +70 °C.
HUMIDITY RANGE
95% UR (non condensing).
EQUIPMENT WEIGHT
Approx. 11 kg.
ACCESSORIES WEIGHT
Approx. 20.5 kg.
DIMENSION
502 x 394 x 190 mm.
AVAILABLE ACCESSORIES
2 Combined test leads (current and potential), clamp type “C” (sargent).
1 Power cord.
1 Ground cable.
1 Communication cable.
1 Carrying case the test leads.
1 License to use the software.